Annual Product Upgrade
 Instructions
It is important to run the latest version of SoftTouch for the best experience for your client. There are a few important steps to take and consider before running an upgrade. Make sure the system is operational to begin with. This means the client is able to go into BackOffice as well as run SoftTouch.
Prepare the system for the Upgrade
 Make sure the Z has run successfully and the merchant is not currently in business hours.
Make sure all checks are closed and client stations are powered down.
Make a backup of the Database from BackOffice. Administration > Data Maintenance > Backup to Local C Drive
Turn off the redundancy. Miscellaneous > DB Maintenance > Activate Data Redundancy > Deactivate Redundancy
Run SoftData which can be found in C:\SoftTouch\SoftData.exe
Select the "Stop all SoftTouch services" option
Go to the printerâs section and make a note of all templates being used by each printer. Hardware > Printers/Coursing > Print Groups
Go to the templates section and save each template to the desktop, naming them accordingly. Administration > Templates
Make sure SoftTouch and BackOffice are closed.
Â
Download the Software Upgrade
Download the most recent version of SoftTouch from Confluence.
Run the program and extract to the C drive in a folder named after the Version. (Ex. 6.5.66E).
Enter the password to allow the extraction to begin: softtouch600
Once extracted, open the folder, and find the SoftTouch Installer.
Â
Begin the Software Upgrade
Click âUpgrade Server Softwareâ in the Installer.
Run through the installation as you normally would. (Leave all defaults alone and follow instructions on screen.)
You may have to click Next twice for the files to begin upgrading.
When the files are upgrading, most of the time, an error will pop up, make sure you keep an eye on it and press Ok when those errors show, or the upgrade will not continue.
Once the files have been upgraded click finish and let the computer reboot twice.
Once itâs back up and running, go back into BackOffice and copy and paste the templates back into the corresponding sections.
Reactivate the redundancy drive. Miscellaneous > DB Maintenance > Activate Data Redundancy > Activate
If you are on version 5.X.X then you may have to manually upgrade all of the Version 5 stations to Version 6 by using the using the "Install "Client & BackOffice" Software" option within the "Client Installations" section of the SoftTouch Installer.
Follow these steps for a smooth upgrade.
Â
Highlight important information in a panel like this one. To edit this panel's color or style, select one of the options in the menu.